{"product_id":"muffle-furnace-1200c-digital-pid","title":"Muffle Furnace 1200°C, Digital PID, Ashing and Heat Treatment","description":"\u003cstyle\u003e.scm-pdp{font-family:'Inter','Helvetica Neue',Arial,sans-serif;color:#0d1b2a;font-size:15.5px;line-height:1.65;max-width:880px}.scm-pdp *{box-sizing:border-box}.scm-pdp h2{font-weight:700;font-size:1.15rem;color:#0d1b2a;margin:24px 0 10px}.scm-pdp p{margin:0 0 14px;color:#2a3f5a}.scm-pdp ul{padding-left:22px;margin:0 0 18px}.scm-pdp li{margin-bottom:6px;color:#2a3f5a}.scm-pdp .lead{font-size:1.02rem;color:#0d1b2a;margin-bottom:18px}.scm-pdp .badges{display:flex;flex-wrap:wrap;gap:8px;margin:14px 0 20px}.scm-pdp .badge{background:#eff6ff;color:#0a4d8c;padding:5px 11px;border-radius:99px;font-size:12.5px;font-weight:600}.scm-pdp table{width:100%;border-collapse:collapse;font-size:14px;margin:14px 0 22px}.scm-pdp th{background:#0d2244;color:#fff;padding:11px 12px;text-align:left;font-weight:700;font-size:13.5px}.scm-pdp td{padding:10px 12px;border-bottom:1px solid #e0e5ec;color:#2a3f5a;font-size:14px}.scm-pdp .highlight{background:#eef7fc;border-left:4px solid #0a4d8c;padding:14px 18px;border-radius:0 8px 8px 0;margin:18px 0;font-size:14.5px;color:#0d2244}.scm-pdp .warn{background:#fee2e2;border-left:4px solid #dc2626;padding:14px 18px;border-radius:0 8px 8px 0;margin:18px 0;font-size:14.5px;color:#7f1d1d}.scm-pdp .b2b{background:linear-gradient(135deg,#0a4d8c 0%,#053867 100%);color:#fff;padding:22px 24px;border-radius:12px;margin:24px 0}.scm-pdp .b2b h3{color:#fff;margin:0 0 10px;font-size:18px}.scm-pdp .b2b p,.scm-pdp .b2b ul li{color:#cbd5e1}\n.scm-pdp .b2b ul{color:#cbd5e1;margin:0 0 14px;padding-left:20px;font-size:14px}.scm-pdp .b2b a{display:inline-block;background:#fff;color:#0a4d8c;padding:9px 18px;border-radius:6px;font-weight:700;text-decoration:none;font-size:14px;margin-right:8px}.scm-pdp details{border:1px solid #d8e8ff;border-radius:8px;margin-bottom:10px;padding:14px 18px}.scm-pdp details summary{font-weight:700;color:#0d2244;cursor:pointer;font-size:.98em}.scm-pdp details p{margin:10px 0 0;color:#3a4a5c;font-size:.94em}.scm-pdp a{color:#0a4d8c;font-weight:600}\/*scm-mobile-v1*\/@media(max-width:640px){.scm-pdp table{font-size:15px}.scm-pdp th,.scm-pdp td{padding:9px 10px;word-break:normal;overflow-wrap:anywhere}.scm-pdp table.scm-stack,.scm-pdp table.scm-stack tbody,.scm-pdp table.scm-stack tr,.scm-pdp table.scm-stack td{display:block;width:100%!important;box-sizing:border-box}.scm-pdp table.scm-stack thead{display:none}.scm-pdp table.scm-stack tr{border:1px solid #d8e2ee;border-radius:10px;margin:0 0 12px;overflow:hidden;background:#fff}.scm-pdp table.scm-stack tr.scm-hrow{display:none}.scm-pdp table.scm-stack td,.scm-pdp table.scm-stack th{display:block;width:100%!important;border-bottom:1px solid #eef2f6;text-align:left}.scm-pdp table.scm-stack td:first-child,.scm-pdp table.scm-stack th:first-child{background:#0d2244;color:#fff;font-weight:700}.scm-pdp table.scm-stack td[data-label]:not(:first-child)::before{content:attr(data-label);display:block;font-size:13.5px;font-weight:700;color:#0a4d8c;margin-bottom:2px}.scm-pdp table.scm-stack td:last-child{border-bottom:0}}\u003c\/style\u003e\n\u003cdiv class=\"scm-pdp\"\u003e\n\n\u003cp class=\"lead\"\u003e\u003cstrong\u003eRectangular industrial muffle furnace with Kanthal wire heating elements on 4-side uniform-distribution grooved refractory, max temperature 1,200°C (working 1,100°C), PID electronic digital temperature controller cum indicator with pyrometer thermocouple.\u003c\/strong\u003e Muffle chamber 225 × 100 × 100mm (9\" × 4\" × 4\"). Silver fuse over-heat protection. ISO \/ CE certified. Ashing, sintering, ceramic firing, gold, silver assay, cement raw mix testing, coal and coke analysis, heat treatment of small metal parts. $4,999 direct, versus $11,000-$18,000 for Nabertherm L 3\/11, Thermo Thermolyne F48000, or Carbolite AAF 11\/3.\u003c\/p\u003e\n\n\u003cdiv class=\"badges\"\u003e\n\u003cspan class=\"badge\"\u003e✓ 1200°C Max Temp\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ Kanthal Wire Elements\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ PID Digital Controller\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ 4-Side Uniform Heating\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ Pyrometer Thermocouple\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ Silver Fuse Protection\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ ISO \/ CE Certified\u003c\/span\u003e\u003cspan class=\"badge\"\u003e✓ 110V \/ 220V\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"highlight\"\u003e\n\u003cstrong\u003eWhere this sits in the market:\u003c\/strong\u003e Nabertherm L 3\/11 muffle furnace (3L, 1100°C): $8,000-$11,000. Thermo Thermolyne F48000 (1.5L, 1093°C): $6,000-$9,000. Carbolite AAF 11\/3 (3L, 1100°C): $10,000-$14,000. Nabertherm LT 5\/12 (5L, 1200°C): $13,000-$18,000. This SciMed muffle furnace delivers the same 1200°C max, same Kanthal wire elements, same PID digital control, same 4-side uniform heat distribution, at $4,999 direct, shipping in 7 business days. Ideal for university teaching labs, small industrial QC facilities, gold and silver assay houses, and specialty chemical \/ cement production sites.\n\u003c\/div\u003e\n\n\u003ch2\u003eWhat a Muffle Furnace Does\u003c\/h2\u003e\n\n\u003cp\u003eA muffle furnace heats samples in a sealed refractory chamber (the \"muffle\") that isolates them from combustion byproducts, critical for accurate ash content, loss on ignition (LOI), gravimetric analysis, and material property testing where contamination would skew results. Kanthal wire heating elements deliver clean, controllable heat up to 1,200°C through a grooved refractory brick liner that surrounds the sample chamber on 4 sides for uniform temperature distribution. The PID digital controller holds setpoint ±3-5°C once equilibrated; the pyrometer thermocouple provides continuous temperature verification.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%\"\u003eMax Temperature\u003c\/th\u003e\n\u003ctd\u003e1,200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous Working Temperature\u003c\/th\u003e\n\u003ctd\u003e1,100°C (recommended for element life)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMuffle Chamber (Internal)\u003c\/th\u003e\n\u003ctd\u003e225 × 100 × 100mm (9\" × 4\" × 4\"), ~2.25 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating Elements\u003c\/th\u003e\n\u003ctd\u003eKanthal wire (FeCrAl alloy), high-temp, oxidation-resistant, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Distribution\u003c\/th\u003e\n\u003ctd\u003e4-side uniform heating (Kanthal wire on all 4 walls)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eHigh-temperature insulating material (ceramic fiber and refractory brick)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOuter Body\u003c\/th\u003e\n\u003ctd\u003eThick mild steel, powder-coated and attractive stoving enamel finish (heavy-gauge G.I.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRefractory\u003c\/th\u003e\n\u003ctd\u003eGrooved brick supporting Kanthal elements (easily replaceable when elements need service)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Control\u003c\/th\u003e\n\u003ctd\u003eElectronic Digital PID Controller cum Indicator (setpoint ± 3-5°C at equilibrium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor\u003c\/th\u003e\n\u003ctd\u003ePyrometer thermocouple (K-type standard, S-type available on request for higher precision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSolid-state silver fuse, protects heating elements against over-heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e220V or 110V AC (specify at order), dedicated 15A circuit typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Power\u003c\/th\u003e\n\u003ctd\u003e2.5-3 kW (varies with heating element configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat-Up Time\u003c\/th\u003e\n\u003ctd\u003eAmbient → 1000°C in ~45-60 minutes typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal Dimensions\u003c\/th\u003e\n\u003ctd\u003e~500 × 450 × 550mm (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e~40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eISO 9001 · CE marked · IEC 61010 electrical safety compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of Origin\u003c\/th\u003e\n\u003ctd\u003eMade in India, quality-assured for export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year parts and labor · Kanthal elements: 6-month (consumable at max temp) or 2-year (at 1000°C working)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eComparison to Alternatives\u003c\/h2\u003e\n\n\u003ctable class=\"scm-stack\"\u003e\u003ctbody\u003e\n\u003ctr class=\"scm-hrow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSciMed Muffle Furnace\u003c\/th\u003e\n\u003cth\u003eNabertherm L 3\/11\u003c\/th\u003e\n\u003cth\u003eThermo Thermolyne F48000\u003c\/th\u003e\n\u003cth\u003eCarbolite AAF 11\/3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003ePrice\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003e\u003cstrong\u003e$4,999\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003e$8,000-$11,000\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003e$6,000-$9,000\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003e$10,000-$14,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eMax temperature\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003e1200°C\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003e1100°C (L 3\/11), 1200°C (LT 5\/12)\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003e1093°C\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003e1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eChamber volume\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003e2.25 L (225×100×100 mm)\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003e3 L\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003e1.5 L\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003e3 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eElements\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003eKanthal wire (FeCrAl)\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003eSilicon carbide and Kanthal\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003eCoiled wire\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003eKanthal wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eHeat distribution\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003e4-side uniform\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003eRing elements\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003eBottom and rear\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003eRing elements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eController\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003ePID digital\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003ePID with programmer\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003ePID digital\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003ePID with 8-segment programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eCertification\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003eISO \/ CE\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003eCE \/ DIN EN 60519\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003eCE \/ UL \/ CSA\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003eCE \/ UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eLead time\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003e7 business days\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003e4-8 weeks\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003e4-6 weeks\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003e6-10 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Feature\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-label=\"SciMed Muffle Furnace\"\u003e1-year parts\u003c\/td\u003e\n\u003ctd data-label=\"Nabertherm L 3\/11\"\u003e2-year\u003c\/td\u003e\n\u003ctd data-label=\"Thermo Thermolyne F48000\"\u003e1-year\u003c\/td\u003e\n\u003ctd data-label=\"Carbolite AAF 11\/3\"\u003e2-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eApplications by Industry\u003c\/h2\u003e\n\n\u003ctable class=\"scm-stack\"\u003e\u003ctbody\u003e\n\u003ctr class=\"scm-hrow\"\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eStandard Method \/ Temperature\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003ePetroleum and coal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eAsh content of coal and coke\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eASTM D3174, D482 (750-815°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eFood and feed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eAsh \/ mineral content\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eAOAC 923.03, 942.05 (550°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eCement and concrete\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eLoss on Ignition (LOI), raw mix testing\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eASTM C114 (950°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eCeramics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eBisque firing, glaze firing, crucible aging\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003e800-1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eGold and silver assay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eCupellation, fire assay\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003e950-1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eEnvironmental testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eVolatile suspended solids (VSS)\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eStandard Methods 2540E (550°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eWaste management\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eIncineration temperature verification\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003e800-1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eMetallurgy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eHeat treatment of small parts, hardening\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003e800-1150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003ePolymers and rubber\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eFiller content, thermal stability\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eASTM E1131 (550-800°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eTextiles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eFiber blend analysis, mineral content\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eAATCC 20A (600°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003ePharma and nutraceutical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eSulphated ash, residue on ignition\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eUSP \u0026lt;281\u0026gt; EP 2.4.14 (600°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eWater treatment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eTotal suspended solids ignition\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003eEPA 160.4 (550°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-label=\"Industry\"\u003e\u003cstrong\u003eAcademic teaching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-label=\"Application\"\u003eGeneral chemistry ash and LOI experiments\u003c\/td\u003e\n\u003ctd data-label=\"Standard Method \/ Temperature\"\u003e500-1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eBest For\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoal and coke testing laboratories\u003c\/strong\u003e: ASTM ash and volatile matter compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCement and concrete QC labs\u003c\/strong\u003e: LOI and raw mix analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and feed testing labs\u003c\/strong\u003e: proximate analysis, mineral content, AOAC ash methods\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic and refractory producers\u003c\/strong\u003e: bisque and glaze firing, crucible pre-conditioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold and silver assay houses\u003c\/strong\u003e: fire assay and cupellation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental testing labs\u003c\/strong\u003e: VSS and water treatment ash content\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharma and nutraceutical QC\u003c\/strong\u003e: USP \u0026lt;281\u0026gt; sulphated ash, residue on ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversity chemistry and materials science teaching labs\u003c\/strong\u003e: undergraduate and graduate courses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall metallurgy shops\u003c\/strong\u003e: heat treatment of small precision parts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolymer and rubber testing labs\u003c\/strong\u003e: thermal stability and filler content\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWaste incineration facilities\u003c\/strong\u003e: combustion efficiency verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational industrial labs\u003c\/strong\u003e (India, LATAM, MENA, SE Asia) via DDP procurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"warn\"\u003e\n\u003cstrong\u003eSafety note:\u003c\/strong\u003e Never operate above 1200°C max rating, Kanthal wire fails rapidly above rated temperature. Recommended continuous working temperature is 1100°C for maximum element life. Provide adequate ventilation (fume hood for combustion gases). Use crucibles and tongs rated for maximum sample temperature. Consult MSDS for specific sample materials before firing.\n\u003c\/div\u003e\n\n\u003ch2\u003eKanthal Wire Heating Elements: Why They Matter\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeCrAl alloy (Kanthal APM \/ A-1)\u003c\/strong\u003e: proprietary iron-chromium-aluminum resistance alloy, forms protective Al₂O₃ oxide layer at operating temperature that resists further oxidation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated to 1250-1400°C\u003c\/strong\u003e depending on grade, comfortable safety margin above our 1200°C max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow creep and long life\u003c\/strong\u003e: Kanthal outlasts Nichrome (max 1150°C) and matches Kanthal Super (MoSi₂) for common lab work at lower cost\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-side placement\u003c\/strong\u003e: top, bottom, and both sides deliver uniform chamber temperature (critical for gravimetric ash accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-replaceable\u003c\/strong\u003e: grooved refractory brick design supports Kanthal replacement in 30-45 minutes without disassembling the entire furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Kanthal wire\u003c\/strong\u003e stocked ($120-180 per set), 5+ year availability from San Jose, California\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"b2b\"\u003e\n\u003ch3\u003eBuying for an Industrial QC Lab, University, or Specialty Testing Facility?\u003c\/h3\u003e\n\u003cp\u003eSciMed supplies muffle furnaces direct to coal, coke labs, cement plants, gold and silver assayers, environmental testing labs, university chemistry departments, and small metallurgy shops globally.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVolume pricing\u003c\/strong\u003e on 3+ unit orders, university teaching lab build-outs, cement plant multi-site rollouts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet-30 invoicing\u003c\/strong\u003e for verified industrial, academic, government facilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSAM.gov and GSA\u003c\/strong\u003e compliant procurement, federal environmental labs, EPA regional labs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 17025 documentation\u003c\/strong\u003e: factory temperature calibration records for lab accreditation submissions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational DDP shipping\u003c\/strong\u003e: India, LATAM, MENA, SE Asia, GCC, UK, EU, AU\/NZ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreight quotes\u003c\/strong\u003e on request, ships crated ~50 kg, US LTL freight typical, ocean for 3+ unit international orders\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS-type thermocouple upgrade\u003c\/strong\u003e: for higher-precision applications (+$300, provides ±1-2°C accuracy vs K-type ±3-5°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom chamber sizes available\u003c\/strong\u003e: 300×150×150mm, 400×200×200mm, and larger on 4-6 week lead time (contact us)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable controller upgrade\u003c\/strong\u003e: 8-segment ramp\/soak programmer +$400 (matches Carbolite AAF specification)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca href=\"mailto:sales@scimedstore.com?subject=Muffle%20Furnace%20procurement%20inquiry\"\u003eEmail procurement →\u003c\/a\u003e\u003ca href=\"tel:+16692659353\"\u003e(669) 265-9353\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat sample size can I fit inside the 225×100×100mm chamber?\u003c\/summary\u003e\u003cp\u003eTypical loads: 4-8 standard 30 mL porcelain crucibles for ashing, or a single ~200 mL ceramic dish for larger loads. For gold and silver assay: 2-3 cupels per firing. Volume ~2.25L is ideal for small-batch analytical work; if you need to run 15+ crucibles per batch or large ceramic pieces, contact us for the larger 300×150×150 or 400×200×200 chamber variants.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eIs this hot enough for gold and silver fire assay?\u003c\/summary\u003e\u003cp\u003eYes. Fire assay cupellation runs at 950-1000°C, well within the 1200°C max rating and comfortable working range. Kanthal elements handle this daily. Assay houses typically use K-type thermocouples for standard work; upgrade to S-type ($300) if you require ±1-2°C precision instead of standard ±3-5°C.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eCan I run 1200°C continuously?\u003c\/summary\u003e\u003cp\u003eNot recommended. 1200°C is the max rating, running there continuously halves Kanthal element life. Recommended continuous working temperature is 1100°C. If you need 1200°C+ regularly, consider our high-temp variant with silicon carbide (SiC) elements rated to 1400°C, email for quote.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat thermocouple type does this use?\u003c\/summary\u003e\u003cp\u003eStandard K-type (Chromel-Alumel), accurate ±3-5°C across the 0-1200°C range, suitable for ashing, LOI, general lab work. S-type (Pt\/Pt-10%Rh) upgrade available for ±1-2°C precision, required for pharma USP \u0026lt;281\u0026gt; residue on ignition and some ceramic industry applications.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat's the heat-up time to 1000°C?\u003c\/summary\u003e\u003cp\u003eTypically 45-60 minutes from ambient to 1000°C. Higher setpoints require proportionally longer (75-90 minutes to 1200°C). The PID controller manages ramp rate automatically; for critical ash-content methods, allow full thermal equilibration (additional 15-20 minutes at setpoint) before starting timed hold.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eDo I need special ventilation?\u003c\/summary\u003e\u003cp\u003eYes, fume hood or dedicated ventilated cabinet is required. Ashing organic samples produces smoke and combustion gases (CO, CO₂, SO₂ from sulfur-containing samples). Never operate in a closed room without ventilation. This is a universal requirement for muffle furnaces, not specific to SciMed.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat voltage?\u003c\/summary\u003e\u003cp\u003eSpecify 110V (standard US 15A circuit) or 220V (international \/ high-power) at order. 220V is preferred for 1200°C operation as heat-up is slightly faster; 110V is fine for continuous 1000°C or below work. Dedicated circuit strongly recommended, don't share with other high-draw equipment.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat's the warranty?\u003c\/summary\u003e\u003cp\u003e1-year parts and labor on outer body, refractory, controller, thermocouple, silver fuse. Kanthal elements: 6-month at max 1200°C use (elements are consumable at max rating) or 2-year warranty when operated at 1000-1100°C working temperature. Replacement Kanthal wire kits stocked in San Jose ($120-180 per set) with 5+ year availability post-purchase.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eIs this ISO 17025 compatible for accredited labs?\u003c\/summary\u003e\u003cp\u003eYes for the equipment side, CE and ISO 9001 manufacturing certifications standard. For ISO 17025 lab accreditation, your calibration provider will perform annual temperature calibration and uncertainty assessment on the installed furnace. Factory calibration records (traceable to NIST or NPL equivalents) included on request.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eHow is this shipped internationally?\u003c\/summary\u003e\u003cp\u003eUS: LTL freight (crated ~50 kg, lift-gate helpful but not required). International: DHL Express DDP for single-unit urgent shipments (~$400-800 depending on country), ocean freight DDP for 3+ unit orders. Ships to India, LATAM (Mexico\/Brazil\/Colombia), MENA (UAE\/Saudi\/Egypt), SE Asia (Vietnam\/Indonesia\/Philippines\/Malaysia), Sub-Saharan Africa (Kenya\/Nigeria\/South Africa), GCC, UK, EU, AU\/NZ.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003ch2\u003eWhy Buy Direct from SciMed\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e~50% of Nabertherm \/ Carbolite pricing\u003c\/strong\u003e: same 1200°C rating, same Kanthal elements, same PID control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShips in 7 business days\u003c\/strong\u003e: faster than typical 4–10 week manufacturer lead times (critical for QC labs replacing failed units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUS-based technical support\u003c\/strong\u003e: installation, controller programming, element replacement guidance from San Jose team\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and academic procurement\u003c\/strong\u003e: SAM.gov, GSA, Net-30, PO acceptance, tax-exempt purchasing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 17025 lab-ready\u003c\/strong\u003e: factory calibration documentation, NIST-traceable references\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKanthal element replacement\u003c\/strong\u003e stocked, 5+ years post-purchase parts availability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrades available\u003c\/strong\u003e: S-type thermocouple, programmable controller, larger chamber, SiC elements for 1400°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational DDP\u003c\/strong\u003e: industrial and academic markets globally\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:8px;padding:14px 18px;margin:24px 0 8px;font-size:14px;color:#374151;line-height:1.55;\"\u003e\u003cstrong\u003eShipping:\u003c\/strong\u003e Continental US LTL freight (~50 kg crated). International DHL Express or ocean freight DDP. Industrial and academic procurement: \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e. Custom duty \/ taxes handled per DDP terms where applicable.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"scimed-manual\" style=\"margin:24px 0;padding:14px 16px;border:1px solid #1f7a8c;border-radius:8px;background:#eef4f7\"\u003e\n\u003ch3 style=\"margin:0 0 6px\"\u003eUser Manual (PDF)\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0578\/9319\/1739\/files\/SciMed-digital-muffle-furnace-1200-c-Operating-Manual.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\u003cstrong\u003eDownload the Operating Manual (PDF)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eBrowse all manuals by category at \u003ca href=\"\/en-au\/pages\/user-manuals\"\u003escimedstore.com\/pages\/user-manuals\u003c\/a\u003e. Need a digital or printed copy, or have a question? Email \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SciMed","offers":[{"title":"Default Title","offer_id":41417134506043,"sku":"SCM-MUFF-FURN-RECT-01","price":4999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/9319\/1739\/files\/scimed-muffle-furnace-rectangular-industrial-max-heating-temp-1200-c-digital-iso-ce.jpg?v=1793432792","url":"https:\/\/scimedstore.com\/en-au\/products\/muffle-furnace-1200c-digital-pid","provider":"SciMed","version":"1.0","type":"link"}