{"product_id":"slit-lamp-haag-streit-type-5-step-applanation-tonometer-beam-splitter-camera","title":"5-Step Slit Lamp, Haag-Streit Type, with Applanation Tonometer, Beam Splitter and Camera","description":"\u003cstyle\u003e.scm-pdp{font-family:'Inter','Helvetica Neue',Arial,sans-serif;color:#0d1b2a;font-size:15.5px;line-height:1.65;letter-spacing:-0.005em;max-width:880px}.scm-pdp *{box-sizing:border-box}.scm-pdp h2{font-weight:700;font-size:1.12rem;letter-spacing:-0.02em;color:#0d1b2a;margin:24px 0 10px;line-height:1.25}.scm-pdp p{margin:0 0 1em;color:#334155}.scm-pdp ul{padding-left:20px;margin:0 0 1em;color:#334155}.scm-pdp ul li{margin-bottom:5px}.scm-pdp .lead{font-size:1.02rem;color:#0d1b2a;margin-bottom:18px}.scm-pdp .badges{display:flex;flex-wrap:wrap;gap:8px;margin:14px 0 20px}.scm-pdp .badges .b{display:inline-flex;align-items:center;gap:6px;background:#eff6ff;color:#0a4d8c;padding:5px 11px;border-radius:99px;font-size:.78rem;font-weight:600}.scm-pdp .specs{width:100%;border-collapse:collapse;font-size:.92rem;margin:14px 0;border:1px solid #e2e8f0;border-radius:8px;overflow:hidden;font-variant-numeric:tabular-nums}.scm-pdp .specs td{padding:11px 14px;border-bottom:1px solid #e2e8f0}.scm-pdp .specs tr:last-child td{border-bottom:0}.scm-pdp .specs td:first-child{color:#64748b;font-weight:500;width:42%;background:#f8fafc}\/*scm-mobile-v1*\/@media(max-width:640px){.scm-pdp table{font-size:15px}.scm-pdp th,.scm-pdp td{padding:9px 10px;word-break:normal;overflow-wrap:anywhere}.scm-pdp table.scm-stack,.scm-pdp table.scm-stack tbody,.scm-pdp table.scm-stack tr,.scm-pdp table.scm-stack td{display:block;width:100%!important;box-sizing:border-box}.scm-pdp table.scm-stack thead{display:none}.scm-pdp table.scm-stack tr{border:1px solid #d8e2ee;border-radius:10px;margin:0 0 12px;overflow:hidden;background:#fff}.scm-pdp table.scm-stack tr.scm-hrow{display:none}.scm-pdp table.scm-stack td,.scm-pdp table.scm-stack th{display:block;width:100%!important;border-bottom:1px solid #eef2f6;text-align:left}.scm-pdp table.scm-stack td:first-child,.scm-pdp table.scm-stack th:first-child{background:#0d2244;color:#fff;font-weight:700}.scm-pdp table.scm-stack td[data-label]:not(:first-child)::before{content:attr(data-label);display:block;font-size:13.5px;font-weight:700;color:#0a4d8c;margin-bottom:2px}.scm-pdp table.scm-stack td:last-child{border-bottom:0}}\u003c\/style\u003e\u003cdiv class=\"scm-pdp\"\u003e\n\u003cp class=\"lead\"\u003e5-step Haag-Streit type slit lamp biomicroscope with integrated applanation tonometer, beam splitter, and digital camera, a complete ophthalmic anterior segment imaging and intraocular pressure measurement system in one chassis. Built for ophthalmology clinics, optometry practices, and teaching hospitals that need slit lamp examination, IOP measurement, and image documentation in a single workflow. Ships from California in 7 business days.\u003c\/p\u003e\n\u003cdiv class=\"badges\"\u003e\n\u003cspan class=\"b\"\u003e5-Step Magnification\u003c\/span\u003e\u003cspan class=\"b\"\u003eHaag-Streit Type\u003c\/span\u003e\u003cspan class=\"b\"\u003eApplanation Tonometer\u003c\/span\u003e\u003cspan class=\"b\"\u003eBeam Splitter and Camera\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eIntegrated System Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-step magnification slit lamp\u003c\/strong\u003e: Haag-Streit type optical system for stepwise zoom across the anterior segment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplanation tonometer\u003c\/strong\u003e: Goldmann-style attachment for accurate intraocular pressure measurement at the slit lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam splitter\u003c\/strong\u003e: routes the optical path between the examiner’s eyepieces and the integrated camera without compromising image quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated camera\u003c\/strong\u003e: captures still and video documentation of slit lamp findings for record-keeping, teaching, and patient communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eClinical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAnterior segment biomicroscopy (cornea, iris, lens, anterior chamber)\u003c\/li\u003e\n\u003cli\u003eIntraocular pressure (IOP) measurement via Goldmann applanation\u003c\/li\u003e\n\u003cli\u003eCataract grading and corneal pathology assessment\u003c\/li\u003e\n\u003cli\u003eConjunctival and lid examination\u003c\/li\u003e\n\u003cli\u003eImage and video documentation of clinical findings\u003c\/li\u003e\n\u003cli\u003eTeaching, telemedicine consultation, and chart documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable class=\"specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical type\u003c\/td\u003e\n\u003ctd\u003eHaag-Streit type slit lamp biomicroscope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e5-step Galilean magnification changer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTonometry\u003c\/td\u003e\n\u003ctd\u003eGoldmann-style applanation tonometer (integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam splitter\u003c\/td\u003e\n\u003ctd\u003eIntegrated, for camera\/observer optical path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImaging\u003c\/td\u003e\n\u003ctd\u003eIntegrated camera for stills and video\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended user\u003c\/td\u003e\n\u003ctd\u003eOphthalmologists, optometrists, teaching hospitals, eye clinics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eComparing models? Read our \u003ca href=\"\/en-ie\/blogs\/eye-care-ophthalmology\/slit-lamp-applanation-tonometer-camera-5-step-guide\"\u003eguide to slit lamps with tonometer and camera\u003c\/a\u003e and \u003ca href=\"\/en-ie\/blogs\/eye-care-ophthalmology\/slit-lamp-buying-guide-2026\"\u003e2-step vs 3-step vs 5-step comparison\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor installation, voltage configuration (110V or 220V), bulk clinic orders, or international procurement, contact \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"scimed-manual\" style=\"margin:24px 0;padding:14px 16px;border:1px solid #1f7a8c;border-radius:8px;background:#eef4f7\"\u003e\n\u003ch3 style=\"margin:0 0 6px\"\u003eUser Manual (PDF)\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0578\/9319\/1739\/files\/SciMed-5-step-slit-lamp-with-applanation-tonometer-beam-splitter-and-camera-Operating-Manual.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\u003cstrong\u003eDownload the Operating Manual (PDF)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eBrowse all manuals by category at \u003ca href=\"\/en-ie\/pages\/user-manuals\"\u003escimedstore.com\/pages\/user-manuals\u003c\/a\u003e. Need a digital or printed copy, or have a question? Email \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SciMed","offers":[{"title":"Default Title","offer_id":41220246143035,"sku":"SCM-SLIT-LAMP-HAAG-01","price":3899.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/9319\/1739\/files\/scimed-slit-lamp-haag-streit-type-5-step-applanation-tonometer-beam-spiltter-camera.jpg?v=1793432587","url":"https:\/\/scimedstore.com\/en-ie\/products\/slit-lamp-haag-streit-type-5-step-applanation-tonometer-beam-splitter-camera","provider":"SciMed","version":"1.0","type":"link"}