{"product_id":"mva-kit-manual-vacuum-aspiration-kit","title":"MVA Manual Vacuum Aspiration Kit — IPAS-Style with 8 Cannulas","description":"\u003cstyle\u003e.scm-pdp{font-family:'Inter','Helvetica Neue',Arial,sans-serif;color:#0d1b2a;font-size:15.5px;line-height:1.65;letter-spacing:-0.005em;max-width:880px}.scm-pdp *{box-sizing:border-box}.scm-pdp h2{font-weight:700;font-size:1.12rem;letter-spacing:-0.02em;color:#0d1b2a;margin:24px 0 10px;line-height:1.25}.scm-pdp p{margin:0 0 1em;color:#334155}.scm-pdp ul{padding-left:20px;margin:0 0 1em;color:#334155}.scm-pdp ul li{margin-bottom:5px}.scm-pdp .lead{font-size:1.02rem;color:#0d1b2a;margin-bottom:18px}.scm-pdp .badges{display:flex;flex-wrap:wrap;gap:8px;margin:14px 0 20px}.scm-pdp .badges .b{display:inline-flex;align-items:center;gap:6px;background:#eff6ff;color:#0a4d8c;padding:5px 11px;border-radius:99px;font-size:.78rem;font-weight:600}.scm-pdp .specs{width:100%;border-collapse:collapse;font-size:.92rem;margin:14px 0;border:1px solid #e2e8f0;border-radius:8px;overflow:hidden;font-variant-numeric:tabular-nums}.scm-pdp .specs td{padding:11px 14px;border-bottom:1px solid #e2e8f0}.scm-pdp .specs tr:last-child td{border-bottom:0}.scm-pdp .specs td:first-child{color:#64748b;font-weight:500;width:42%;background:#f8fafc}.scm-pdp .faq details{border-bottom:1px solid #e2e8f0;padding:10px 0}.scm-pdp .faq summary{cursor:pointer;font-weight:600;color:#0d1b2a;padding:6px 0;font-size:.96rem}.scm-pdp .faq details p{padding:8px 0 4px;color:#334155}\u003c\/style\u003e\u003cdiv class=\"scm-pdp\"\u003e\n\u003cp class=\"lead\"\u003eThe \u003cstrong\u003eMVA Kit (Manual Vacuum Aspiration Kit)\u003c\/strong\u003e is a complete \u003cstrong\u003eIPAS-style\u003c\/strong\u003e uterine evacuation system for managing incomplete miscarriage and other first-trimester obstetric procedures at 5–12 weeks of gestation. Includes a double-valve MTP syringe and 8 sterile Karman cannulas (4, 5, 6, 7, 8, 9, 10, 12 mm) with atraumatic rounded tips and lateral eyes for smooth uterine cavity access.\u003c\/p\u003e\n\u003cdiv class=\"badges\"\u003e\n\u003cspan class=\"b\"\u003eIPAS-Style\u003c\/span\u003e\u003cspan class=\"b\"\u003eDouble-Valve MTP Syringe\u003c\/span\u003e\u003cspan class=\"b\"\u003e8 Karman Cannulas\u003c\/span\u003e\u003cspan class=\"b\"\u003eMedical-Grade Polypropylene\u003c\/span\u003e\u003cspan class=\"b\"\u003eSterile\u003c\/span\u003e\u003cspan class=\"b\"\u003eSingle-Use per Patient\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhat is Manual Vacuum Aspiration (MVA)?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eManual Vacuum Aspiration (MVA)\u003c\/strong\u003e is a WHO-recommended first-trimester uterine evacuation technique using a hand-held vacuum syringe rather than electric suction. MVA is used for incomplete or missed miscarriage management, post-abortion care (PAC), endometrial biopsy, and elective first-trimester procedures where electric suction is unavailable or contraindicated. The technique is faster, quieter, and requires no electricity — making it the standard uterine evacuation method in outpatient OB-GYN settings, humanitarian medicine, and low-resource settings.\u003c\/p\u003e\n\u003ch2\u003eClinical applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManagement of incomplete or missed miscarriage (5–12 weeks gestation)\u003c\/li\u003e\n\u003cli\u003ePost-abortion care (PAC) uterine evacuation\u003c\/li\u003e\n\u003cli\u003eElective first-trimester termination of pregnancy (in jurisdictions where permitted)\u003c\/li\u003e\n\u003cli\u003eEndometrial biopsy \/ diagnostic aspiration\u003c\/li\u003e\n\u003cli\u003eRetained products of conception (RPOC) management\u003c\/li\u003e\n\u003cli\u003eOutpatient OB-GYN under local anesthesia or paracervical block\u003c\/li\u003e\n\u003cli\u003eHumanitarian medicine and NGO obstetric services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow Manual Vacuum Aspiration (MVA) works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the syringe\u003c\/strong\u003e — connect the double-valve MTP syringe and depress the plunger to lock the vacuum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect appropriate cannula\u003c\/strong\u003e — sizing (mm) typically matches gestational age in weeks; e.g., 5 mm cannula for 5 weeks, 8 mm for 8 weeks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttach cannula\u003c\/strong\u003e to the syringe via the supplied connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition patient\u003c\/strong\u003e in dorsal lithotomy with paracervical block anesthesia\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert cannula\u003c\/strong\u003e through the cervix under sterile technique\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelease vacuum\u003c\/strong\u003e — flip the valve to release the held vacuum through the cannula\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotate and aspirate\u003c\/strong\u003e — 360° rotations of the cannula while gradually advancing to systematically evacuate the uterine cavity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm complete evacuation\u003c\/strong\u003e — gritty sensation on cannula, no more tissue in syringe, cavity feels empty on bimanual exam\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithdraw and inspect\u003c\/strong\u003e — visualize aspirated products of conception to confirm complete procedure\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable class=\"specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe type\u003c\/td\u003e\n\u003ctd\u003eDouble-valve IPAS-style manual vacuum aspirator (MTP syringe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCannulas included\u003c\/td\u003e\n\u003ctd\u003e8 sizes — 4, 5, 6, 7, 8, 9, 10, 12 mm Karman cannulas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCannula tip\u003c\/td\u003e\n\u003ctd\u003eSmooth rounded tip with lateral atraumatic eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCannula material\u003c\/td\u003e\n\u003ctd\u003eMedical-grade polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum\u003c\/td\u003e\n\u003ctd\u003eUp to 24 inHg (~610 mmHg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eEach cannula individually sterile-packed in peelable pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse\u003c\/td\u003e\n\u003ctd\u003eSingle-use per patient (cannulas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusability\u003c\/td\u003e\n\u003ctd\u003eSyringe is autoclavable \/ reprocessable per IPAS protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~180 g (kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended user\u003c\/td\u003e\n\u003ctd\u003eOB-GYN clinicians, PAC services, women's health clinics, hospital ED, humanitarian medicine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Double-valve MTP syringe (60 mL)\u003c\/li\u003e\n\u003cli\u003e8 × Karman cannulas (4, 5, 6, 7, 8, 9, 10, 12 mm) — individually sterile-packed\u003c\/li\u003e\n\u003cli\u003e1 × Set of adapter connectors\u003c\/li\u003e\n\u003cli\u003e1 × Silicone lubricating oil\u003c\/li\u003e\n\u003cli\u003eSterile peelable pouch packaging (per cannula)\u003c\/li\u003e\n\u003cli\u003eOuter carton with lot \/ expiry markings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdiv class=\"faq\"\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this MVA kit IPAS-compatible?\u003c\/summary\u003e\u003cp\u003eYes. The syringe and cannulas follow the IPAS MTP double-valve design standard used by IPAS-trained providers worldwide. All 8 cannula sizes correspond to the standard IPAS gestational-age sizing (4-12 mm).\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat sizes of cannulas come in the kit?\u003c\/summary\u003e\u003cp\u003eEight (8) Karman cannulas: 4 mm, 5 mm, 6 mm, 7 mm, 8 mm, 9 mm, 10 mm, 12 mm. Cannula sizing (mm) typically matches gestational age in weeks — e.g., 5 mm for 5 weeks, 8 mm for 8 weeks. Having all sizes in one kit means no need to reorder mid-procedure if gestational dating was off.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs manual vacuum aspiration safer than sharp curettage (D\u0026amp;C)?\u003c\/summary\u003e\u003cp\u003eMultiple RCT and cohort studies (Grimes 2004, Tunçalp 2010) show MVA has lower rates of uterine perforation, less blood loss, less pain, and shorter procedure time compared to sharp curettage for first-trimester uterine evacuation. WHO recommends MVA over sharp curettage for incomplete miscarriage management.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I reuse the MVA syringe?\u003c\/summary\u003e\u003cp\u003eThe double-valve syringe is designed to be autoclavable and reprocessable per IPAS reprocessing protocols. The cannulas, however, are single-use per patient and must be discarded after one procedure.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat anesthesia is used for MVA?\u003c\/summary\u003e\u003cp\u003eParacervical block with 1% lidocaine is standard for outpatient MVA. Additional oral or IV analgesia (NSAIDs ± opioid) may be added for patient comfort. General anesthesia is not required for standard first-trimester MVA.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eUp to how many weeks of gestation can MVA be used?\u003c\/summary\u003e\u003cp\u003eMVA is validated for first-trimester procedures up to 12 weeks (menstrual age). Beyond 12 weeks, electric vacuum aspiration (EVA) or dilation and evacuation (D\u0026amp;E) is typically used per WHO and ACOG guidance.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDoes the MVA kit meet WHO essential medicines standards?\u003c\/summary\u003e\u003cp\u003eYes. The MVA kit design meets WHO essential medicines standards for uterine evacuation equipment and is suitable for humanitarian medicine, low-resource settings, and NGO obstetric services.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I bulk-order MVA kits for a hospital or humanitarian program?\u003c\/summary\u003e\u003cp\u003eYes. Email \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e for pricing on 10+ unit orders. Humanitarian NGO programs and teaching hospitals receive institutional pricing.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAlso known as\u003c\/h2\u003e\n\u003cp\u003eMVA kit · Manual Vacuum Aspiration kit · IPAS-style MVA kit · MTP syringe kit · Karman cannula kit · uterine evacuation kit · miscarriage management kit · post-abortion care kit · PAC kit\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor hospital procurement, women's health programs, humanitarian NGO orders, or MVA training kit orders, contact \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e or \u003ca href=\"tel:+16692659353\"\u003e(669) 265-9353\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"MedicalDevice\",\"name\":\"MVA Manual Vacuum Aspiration Kit - IPAS-Style with 8 Cannulas\",\"alternateName\":[\"MVA kit\",\"Manual Vacuum Aspiration kit\",\"IPAS-style MVA kit\",\"MTP syringe kit\",\"Karman cannula kit\",\"uterine evacuation kit\",\"PAC kit\"],\"description\":\"IPAS-style manual vacuum aspiration kit with double-valve MTP syringe and 8 Karman cannulas (4-12 mm) for first-trimester uterine evacuation, incomplete miscarriage management, and post-abortion care.\",\"category\":\"Obstetric procedure kit\",\"purpose\":\"First-trimester uterine evacuation and post-abortion care\"}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is this MVA kit IPAS-compatible?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The syringe and cannulas follow the IPAS MTP double-valve design standard used by IPAS-trained providers worldwide. All 8 cannula sizes correspond to the standard IPAS gestational-age sizing (4-12 mm).\"}},{\"@type\":\"Question\",\"name\":\"What sizes of cannulas come in the kit?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Eight Karman cannulas: 4 mm, 5 mm, 6 mm, 7 mm, 8 mm, 9 mm, 10 mm, 12 mm. Sizing typically matches gestational age in weeks.\"}},{\"@type\":\"Question\",\"name\":\"Is manual vacuum aspiration safer than sharp curettage?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Multiple RCT and cohort studies show MVA has lower rates of uterine perforation, less blood loss, less pain, and shorter procedure time compared to sharp curettage. WHO recommends MVA over sharp curettage for incomplete miscarriage management.\"}},{\"@type\":\"Question\",\"name\":\"Can I reuse the MVA syringe?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The double-valve syringe is designed to be autoclavable and reprocessable per IPAS reprocessing protocols. Cannulas are single-use per patient.\"}},{\"@type\":\"Question\",\"name\":\"What anesthesia is used for MVA?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Paracervical block with 1% lidocaine is standard for outpatient MVA. Additional oral or IV analgesia may be added. General anesthesia is not required.\"}},{\"@type\":\"Question\",\"name\":\"Up to how many weeks of gestation can MVA be used?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MVA is validated for first-trimester procedures up to 12 weeks menstrual age. Beyond 12 weeks, electric vacuum aspiration or D\u0026E is typically used.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scimedstore.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Obstetrics\",\"item\":\"https:\/\/scimedstore.com\/collections\/medical-equipments\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MVA Manual Vacuum Aspiration Kit\",\"item\":\"https:\/\/scimedstore.com\/products\/mva-kit-manual-vaccum-aspiration-kit\"}]}\u003c\/script\u003e\n\u003cdiv class=\"scimed-manual\" style=\"margin:24px 0;padding:14px 16px;border:1px solid #1f7a8c;border-radius:8px;background:#eef4f7\"\u003e\n\u003ch3 style=\"margin:0 0 6px\"\u003eUser Manual (PDF)\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0578\/9319\/1739\/files\/SciMed-manual-vacuum-aspiration-mva-kit-with-8-cannulas-Instructions-for-Use.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\u003cstrong\u003eDownload the Instructions for Use (PDF)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eBrowse all manuals by category at \u003ca href=\"\/en-no\/pages\/user-manuals\"\u003escimedstore.com\/pages\/user-manuals\u003c\/a\u003e. Need a digital or printed copy, or have a question? Email \u003ca href=\"mailto:sales@scimedstore.com\"\u003esales@scimedstore.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SciMed","offers":[{"title":"Default Title","offer_id":40678761463867,"sku":"AY1EV167","price":299.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/9319\/1739\/products\/IpasMVAPlusManualVacuumAspirationMVAKitNewFreeShipping1.jpg?v=1705534735","url":"https:\/\/scimedstore.com\/en-no\/products\/mva-kit-manual-vacuum-aspiration-kit","provider":"SciMed","version":"1.0","type":"link"}