Laboratory & Scientific Equipment

Manual Capsule Filling Machine Guide: Sizes, Th...

A manual 100-hole capsule filling machine lets a small team fill hard-shell capsules in batches of 100 using plates, an orienter, and a tamping tool, with no electricity required. It...

Manual Capsule Filling Machine Guide: Sizes, Th...

A manual 100-hole capsule filling machine lets a small team fill hard-shell capsules in batches of 100 using plates, an orienter, and a tamping tool, with no electricity required. It...

How to Choose a Muffle Furnace for Ashing, Sint...

A muffle furnace heats samples inside an insulated chamber, separated from the heating elements and any combustion products, so the result reflects the sample rather than the furnace. Labs use...

How to Choose a Muffle Furnace for Ashing, Sint...

A muffle furnace heats samples inside an insulated chamber, separated from the heating elements and any combustion products, so the result reflects the sample rather than the furnace. Labs use...

Automated vs Manual Melting Point Apparatus: Wh...

Melting point is one of the quickest ways to check the identity and purity of a crystalline solid. A pure compound melts sharply over a narrow range; impurities usually lower...

Automated vs Manual Melting Point Apparatus: Wh...

Melting point is one of the quickest ways to check the identity and purity of a crystalline solid. A pure compound melts sharply over a narrow range; impurities usually lower...

Vertical Autoclave Buying Guide: Sizes, Constru...

A vertical autoclave is a top-loading steam sterilizer: you lower loads into a cylindrical chamber, lock the lid, and the unit heats water to produce pressurized steam. It is a...

Vertical Autoclave Buying Guide: Sizes, Constru...

A vertical autoclave is a top-loading steam sterilizer: you lower loads into a cylindrical chamber, lock the lid, and the unit heats water to produce pressurized steam. It is a...

How to Choose a BOD Incubator for 5-Day BOD Tes...

If your lab runs the 5-day biochemical oxygen demand (BOD) test, the incubator is the one piece of equipment that has to hold steady for 120 hours without anyone watching...

How to Choose a BOD Incubator for 5-Day BOD Tes...

If your lab runs the 5-day biochemical oxygen demand (BOD) test, the incubator is the one piece of equipment that has to hold steady for 120 hours without anyone watching...

Disposable blade holder for rotary microtome

Microtome Section Problems Solved: Chatter, Thi...

A practical troubleshooting checklist for rotary microtome chatter, alternating thick and thin sections and other common faults, starting with blade holder setup.

Microtome Section Problems Solved: Chatter, Thi...

A practical troubleshooting checklist for rotary microtome chatter, alternating thick and thin sections and other common faults, starting with blade holder setup.