Skip to product information
1 of 6

SciMed

Flocculation Jar Test Apparatus, 6 Jar, 5-150 RPM Digital, LED Lit

Flocculation Jar Test Apparatus, 6 Jar, 5-150 RPM Digital, LED Lit

Regular price $1,499.99 USD
Regular price Sale price $1,499.99 USD
Sale Sold out
Doctor Recommended
No Rx Required
Ships Same-Day
30-Day Size Exchange — sealed, unopened packs
Taxes included. Shipping calculated at checkout.
Spindle

Flocculation jar test apparatus for water, wastewater treatment coagulation optimization, determines optimum coagulant dose, mixing energy, and pH for turbidity, color and organic matter removal. Available in 2, 4, or 6 jar configurations for 1000 mL beakers. Digital variable speed control 5-150 RPM ±1 RPM accuracy, 12mm red LED display, individually removable stainless steel stirring paddles (removable without disturbing other stirrers), acrylic-base cold-light illuminator (fluorescent lamps) for floc visualization. Choose 2-jar ($1,499), 4-jar ($1,799), or 6-jar ($1,999) at checkout. For municipal and industrial water treatment plants, environmental testing labs, and academic environmental engineering programs.

✓ 2 / 4 / 6 Jar Configs✓ 5-150 RPM Digital ±1 RPM✓ 1000 mL Beakers✓ SS Paddles (Removable)✓ Cold-Light LED Base✓ 12mm LED Display✓ 110V or 220V✓ EPA / AWWA Method
Where this sits in the market: Phipps & Bird PB-700 six-paddle jar tester: $4,500-$6,500. Velp Scientifica JLT6: $3,500-$5,000. Hanna HI-190M jar test: $3,000-$4,500. This SciMed jar test apparatus delivers the same clinical function, 5-150 RPM digital variable speed, individually-removable SS paddles, 1000 mL round beakers, cold-light acrylic illuminator for floc visualization, at 30-50% of Western OEM pricing. Ideal for municipal and industrial water treatment plants running daily coagulant dose optimization, environmental testing labs, and university environmental engineering programs.

Configuration Selection

Variant Jars Best For Price
2-jar 2 × 1000 mL beakers Small water plant and benchtop screening, university teaching lab $1,499.99
4-jar 4 × 1000 mL beakers Standard water and wastewater plant daily coag optimization $1,799.99
6-jar 6 × 1000 mL beakers Full method-of-standard-additions coag dose curve, standard EPA / AWWA approach $1,999.99

Why Jar Testing Matters for Water Treatment

Optimum coagulant dose (alum, PAC, ferric chloride, polymer) varies with raw water quality (turbidity, alkalinity, pH, organics, temperature). Overdosing wastes chemistry and generates excess sludge. Underdosing lets floc pass into filters and causes finished-water turbidity. The jar test simulates full-scale coagulation → flocculation → sedimentation in a benchtop 6-jar array, dosing each jar with a different coagulant amount, running standard mixing energy profile (rapid mix 100 RPM × 30 sec → slow mix 30 RPM × 15 min → settle 15 min), then measuring residual turbidity to find the dose that gives lowest residual at lowest cost. Municipal and industrial water plants run this test daily; changes in raw water source (rain events, algal blooms, seasonal shifts) require dose re-optimization. Method 2540 and AWWA Standard Methods 2560 recognize jar testing as the primary coag optimization technique.

Specifications

Jar Configurations 2, 4, or 6 × 1000 mL beakers (select at order)
Speed Range 5 to 150 RPM (continuously variable)
Speed Accuracy ±1 RPM
Display 12 mm red LED digital display, current RPM readout
Stirring Paddles Stainless steel, standard flat-blade design, individually removable
Paddle Removal Individual paddles removable without disturbing other running stirrers
Illumination Cold-light fluorescent illuminator, diffused through acrylic sheet base, clear floc visualization
Beaker Holder Base Acrylic light-diffusing base (also protects fluorescent lamp)
Dimensions 930 × 250 × 480 mm (L × W × H), 6-jar variant
Power 110V or 220V, 50/60 Hz (specify at order)
Warranty 1-year parts and labor

Standard Jar Test Method

  1. Fill each jar with 1000 mL of raw water sample
  2. Dose different coagulant amounts in each jar (e.g. 10 / 20 / 30 / 40 / 50 / 60 mg/L alum)
  3. Rapid mix at 100 RPM for 30 seconds (simulates plant flash mixer)
  4. Slow mix at 30 RPM for 15 minutes (simulates plant flocculator)
  5. Stop paddles: allow 15-30 minutes settling
  6. Sample supernatant from each jar, measure residual turbidity (NTU)
  7. Plot residual turbidity vs coag dose: optimum dose = lowest residual turbidity and minimum coag cost

Applications

  • Municipal drinking water treatment plants: daily coagulant optimization
  • Industrial wastewater treatment: food processing, pulp and paper, textile dye, mining, chemical plants
  • Stormwater treatment: construction runoff, agricultural runoff
  • Environmental testing laboratories: contract water testing and treatability studies
  • Water research and treatment optimization: polymer selection, PAC vs alum comparison, pH sensitivity
  • Cooling tower and boiler water treatment: makeup water coag prior to demineralization
  • Aquaculture and fish farm water treatment
  • University and college civil / environmental engineering programs: teaching lane equipment
  • NGO and humanitarian water treatment: emergency and refugee water treatment training

Best For

  • Municipal drinking water plants (0.5 - 100+ MGD)
  • Industrial wastewater treatment plants (food/beverage, pulp+paper, textile)
  • Environmental engineering and water research labs
  • State and regional water quality regulatory agencies
  • University civil and environmental teaching labs
  • International municipal water development (India, Sub-Saharan Africa, LATAM, SE Asia)
  • NGO and humanitarian water treatment training

Buying for a Water Plant, Environmental Lab, or University?

  • Volume pricing on 3+ orders, university teaching lab fleets, multi-plant municipal orders
  • Net-30 invoicing for verified municipalities, environmental labs, universities
  • SAM.gov / GSA compliant procurement for federal and state agencies
  • Replacement paddles ($60), acrylic base ($150), fluorescent lamps ($20) stocked in San Jose
  • Compatible with standard water treatment jar test protocols (AWWA / EPA / Standard Methods 2540 and 2560)
  • International DDP shipping, massive municipal water expansion in India, Sub-Saharan Africa, LATAM
  • Complete jar test kit, beakers, coagulant syringes, timers, worksheets included on request
Email procurement →(669) 265-9353

FAQ

How does this compare to Phipps & Bird PB-700?

Feature parity, 5-150 RPM digital variable speed, individually removable paddles, cold-light illuminator base, 6-jar configuration. Phipps & Bird PB-700 has slightly more polished operator interface and integrated timer. Price differential: $1,999 (6-jar) vs $4,500-$6,500 for PB-700. For municipal plants and universities, our unit delivers full method compliance at 30-40% of P&B pricing.

What jar size does this use?

Standard 1000 mL round beakers (B34 pattern), compatible with standard AWWA jar test method. 6 × 1000 mL beakers included in 6-jar configuration.

How do I select 2 / 4 / 6 jar variant?

Select at checkout. 2-jar for benchtop screening and small water plants. 4-jar for standard mid-size plant coag optimization. 6-jar for full method-of-standard-additions (most municipal water plants and universities standardize on 6-jar).

What voltage do I need?

Specify 110V/60Hz (US standard) or 220V/50Hz (international) at order. Email sales@scimedstore.com if uncertain.

Can I use square jars instead of round beakers?

Square jars (2-liter Phipps & Bird style) provide slightly better flocculation dynamics but round 1000 mL beakers are AWWA standard method compliant. Round beakers are cheaper and universally available. Square jars available as accessory upgrade on request.

User Manual (PDF)

Download the Operating Manual (PDF)

Browse all manuals by category at scimedstore.com/pages/user-manuals. Need a digital or printed copy, or have a question? Email sales@scimedstore.com.

View full details