SciMed
8-Channel Multichannel Micropipette, 0.5 to 300 μL, 360° Rotating Head
8-Channel Multichannel Micropipette, 0.5 to 300 μL, 360° Rotating Head
Couldn't load pickup availability
8-channel variable-volume multi-channel micropipette, the essential tool for microtiter plate work in immunology, clinical diagnostics, biochemistry, and food analysis. Air-displacement principle with detachable disposable tips. 6 volume-range variants available: 0.5-10 μL / 2-20 μL / 5-50 μL / 10-100 μL / 20-200 μL / 30-300 μL. 360° rotating tip head lets operator work at any comfortable angle. Integrated tip ejector for hygienic single-handed tip changes. All variants $349.
Volume Range Variants
| Variant | Volume Range | Best For |
|---|---|---|
| 0.5-10 μL | Low-volume | PCR mastermix per-well dispensing, high-density microarrays |
| 2-20 μL | Low-volume | ELISA sample loading, cell culture assay setup |
| 5-50 μL | Mid-low | Standard curve prep, dilution series |
| 10-100 μL | Mid-volume | Standard ELISA and immunoassay workflow (workhorse) |
| 20-200 μL | Mid-volume | 96-well plate general purpose (workhorse) |
| 30-300 μL | High volume | High-volume dispensing, wash steps, media exchange |
Specifications
| Type | 8-channel variable-volume multi-channel air-displacement micropipette |
|---|---|
| Working Principle | Air-displacement (piston, air interface and disposable tip) |
| Volume Adjustment | Continuously adjustable via digital counter |
| Number of Channels | 8 (standard for 96-well plate workflow) |
| Rotating Head | 360°, operator can work at any angle |
| Accuracy | ±5.0% (low volume) to ±1.0% (high volume) across range |
| Precision (CV%) | <2.50% (low volume) to <0.40% (high volume) |
| Tip Ejector | Integrated single-handed ejector |
| Tip Compatibility | Universal, Eppendorf, Rainin, ART, and generic tips |
| Autoclave | Fully autoclavable at 121°C |
| Warranty | 1-year against manufacturing defects |
Applications
- ELISA and immunoassay: sample loading, wash buffer dispensing, TMB substrate
- Clinical diagnostics: 96-well plate patient sample processing
- Molecular biology: PCR plate setup, RT-qPCR mastermix
- Cell culture: media exchange in 96-well culture plates
- Biochemistry: protein quantification, enzyme assays
- Food analysis: food safety and allergen ELISA
- Water quality analysis: 96-well titration
- Dilution series prep: 8-channel serial dilution across plates
- University teaching: molecular biology and immunology courses
Best For
- Clinical diagnostic labs (ELISA and serology workflow)
- Molecular biology and PCR labs
- Cell culture facilities
- Pharmaceutical QC and R&D labs (high-throughput assay)
- Food safety and allergen testing labs
- Water quality analysis labs
- Contract testing organizations
- University teaching labs
- International lab procurement via DDP
Buying for a Lab or Program?
- Volume pricing on 5+ orders (single or mixed variant sets)
- Net-30 invoicing for verified accounts
- Multi-variant bundle, one of each volume range at bundle discount
- Annual ISO 8655 calibration service, send-in with certificate
- Replacement tip cones and seals stocked
- International DDP shipping, biotech and diagnostic markets globally
- Universal 96-well plate tip bulk pricing on 10+ box orders
FAQ
Which variant should I get first?
20-200 μL is the workhorse for 96-well plate ELISA workflow, start here. Add 2-20 μL next (low-volume ELISA loading) and 30-300 μL third (wash and media exchange). Full 6-variant set covers every standard microtiter plate application.
How does this compare to Rainin E8-200 XLS or Eppendorf Xplorer plus?
Feature parity on core function, 8 channels, air displacement, universal tips, rotating head. Rainin XLS, Eppendorf Xplorer have electronic motorized volume and precision at ±0.5% consistently. Ours is manual with mechanical accuracy dropping to ±1-5% at extreme range ends. Price differential: $349 vs $1,500-$3,500. For general microplate work, ours is adequate; for high-throughput regulated pharma work with GMP and LIMS integration, motorized units are preferred.
Is this autoclavable?
Yes at 121°C for 20 min. Fully assembled autoclave, do not disassemble before sterilization.
Which tips fit?
Universal, any 8-channel 96-well plate compatible pipette tips fit (Eppendorf, Rainin, ART, generic).
User Manual (PDF)
Download the Operating Manual (PDF)
Browse all manuals by category at scimedstore.com/pages/user-manuals. Need a digital or printed copy, or have a question? Email sales@scimedstore.com.
Share
