SciMed
Universal Optical Trial Frame — Fully Adjustable 48-80mm PD, 360° Rotation, 74g Ultralight, Optometry Refraction Standard
Universal Optical Trial Frame — Fully Adjustable 48-80mm PD, 360° Rotation, 74g Ultralight, Optometry Refraction Standard
Couldn't load pickup availability
Universal fully-adjustable optical trial frame — the primary refraction-lane instrument for every optometry practice, ophthalmology clinic, and low-vision service. Adjustable PD 48-80mm (accommodates children through adults with wide IPD), temple length 98-135mm, nose bridge height 0-14mm, adjustable nose angle 0-30° for individual facial anatomy. Full 360° lens rotation with independent axis calibration on each cell (left −120° to 0° to 135°, right +45° to 180° to 60°) for precise cylinder axis positioning. Ultralight 74g total weight — critical for patient comfort during 15-20 min refractions. $249.99 direct — versus $500-$900 for Oculus UB4 / Topcon TT-01 / Reichert 12871 / Marco M-25 branded universal trial frames.
Applications
- Primary refraction lane — subjective refraction in every optometry / ophthalmology practice (this IS the primary frame)
- Pediatric refraction — narrow PD adjustment (min 48mm) fits school-age children
- Low vision refraction — accommodates decentered lens positioning + trial magnifiers
- Post-cataract refraction — adjustable frame accommodates surgical hardware + patient anatomy variations
- Contact lens over-refraction — refract over patient's contacts to fine-tune Rx
- Prism refraction (strabismus, diplopia) — hold prism trial lenses in cell for alignment testing
- Community + rural eye clinics — primary refraction tool
- Screening camps — one universal frame + several fixed-PD backup frames (SciMed 64mm $249)
Specifications
| PD range | 24-40mm each side · 48-80mm total (both eyes) — pediatric through wide-IPD adult |
|---|---|
| Temple length | 98-135mm adjustable (short to long head) |
| Nose bridge height | 0-14mm adjustable (fits low to high nasal bridge anatomy) |
| Nose angle | 0°-30° adjustable (accommodates facial anatomy variation) |
| Axis calibration | Left cell: −120° to 0° to 135° · Right cell: +45° to 180° to 60° (independent for each eye) |
| Lens rotation | Full 360° per cell |
| Weight | 74g total (ultralight — no patient fatigue during long refractions) |
| Cell compatibility | Universal 38mm cell diameter (all standard optometry trial lens sets) |
| Warranty | 1-year against manufacturing defects |
Comparison to premium OEMs
| Feature | SciMed Universal | Oculus UB4 | Topcon TT-01 | Marco M-25 |
|---|---|---|---|---|
| PD range | 48-80mm | 48-80mm | 50-80mm | 48-80mm |
| Temple length | 98-135mm | 98-140mm | 100-135mm | 100-135mm |
| Nose bridge adj | 0-14mm | Yes | Yes | Yes |
| Weight | 74g | 62g | 68g | 75g |
| Axis calibration | Independent L/R | Independent L/R | Independent L/R | Independent L/R |
| Cell diameter | 38mm universal | 38mm | 38mm | 38mm |
| Price | $249.99 | $650-$750 | $550-$650 | $500-$600 |
Best for
- Primary refraction lane in optometry + ophthalmology practices
- Pediatric refraction lanes (narrow PD critical)
- Optometry / ophthalmology residency training (primary teaching frame)
- Community + rural eye clinics
- International eye NGOs — Aravind, LV Prasad, Fred Hollows, Sightsavers, ORBIS
- Mobile refraction service providers
- International DDP procurement — global refraction lane setups
Buying for a practice, residency, or eye NGO?
- Volume pricing on 3+ frames (equip multi-lane practice or residency cohort)
- Net-30 invoicing for verified academic + NGO + practice accounts
- SAM.gov / VA compliant for federal + academic ophthalmology
- Bundle with SciMed fixed-64mm frame ($249) + trial lens sets — refraction-lane package deals
- International DDP — global eye-care procurement
FAQ
Universal vs fixed-PD frame — which do I need?
Both. Universal (this frame) = primary refraction-lane tool, adjustable to any patient anatomy from child to adult. Fixed-PD (SciMed 64mm, $249) = backup / spare / camp frame, faster to seat on adult patients when high throughput matters. A well-equipped practice has both.
Why the specific axis calibration ranges?
Axis scales are marked from the perspective of each eye (patient's convention, not TABO). Left cell (patient's left = provider's right): reads −120° through 0° (horizontal) to +135°. Right cell mirrors this. Standard optometry convention — no re-training needed for staff familiar with any commercial trial frame.
Trial lens set compatibility?
Universal 38mm cell — accepts any standard optometry trial lens set (SciMed sets, Marco, Reichert, Topcon, Oculus, generic 232-piece or 266-piece sets). No proprietary lock-in.
Compared to premium Oculus / Topcon — what's the trade-off?
Oculus / Topcon are precision German/Japanese optical instruments with tighter machining tolerances, longer service life, and industry-leading axis calibration precision. This SciMed frame delivers functional refraction-lane accuracy at 30-40% of premium OEM pricing. For a high-volume specialty practice, invest in Oculus. For general optometry, residencies, community clinics, NGO programs, and satellite offices, SciMed hits the value sweet spot.
User Manual (PDF)
Download the Instructions for Use (PDF)
Browse all manuals by category at scimedstore.com/pages/user-manuals. Need a digital or printed copy, or have a question? Email sales@scimedstore.com.
Share